Generates a warning when an overlapping PERFORM range is detected in the program. 
                  	  
               
            
 
            	 
             
               		
               Restriction:  This directive is supported for managed COBOL only. 
                  
               
 
               	 
              
            	 
            
               Syntax:
 
               		 
               		>>--.---.-.----.-ILSHOWPERFORMOVERLAP---><
    +-/-+ +-NO-+ 
               	   
            	 
             
            	 
            
               Properties:
 
               		 
               		
               
                   
                     			  
                     			  
                     			 
                      
                        				
                         
                           				  
                           | Default: | Not set | 
 
                        				
                         
                           				  
                           | Phase: | Any | 
 
                        				
                         
                           				  
                           | IDE equivalent | None | 
 
                        			 
                      
                     		  
                  
                 
               	 
              
            	 
             
            
           
         
         
Example:
In the example below, the PERFORM ranges a thru c, c thru f and f [thru f] overlap each other. By setting ILSHOWPERFORMOVERLAP, two warnings are produced: COBCH1663 to indicate the start of the first affected range and the number of overlapping PERFORM ranges, and COBCH1664 to indicate the start of each range affected.
$set ilshowperformoverlap ... perform a thru c. perform c thru f. perform f. goback. *> errors are displayed as follows: a section. display "Running section a.". *> COBCH1663E Overlapping perform range: 3 entries *> COBCH1664E perform range: a thru c b section. display "Running section b.". c section. *> COBCH1664E perform range: c thru f display "Running section c.". d section. display "Running section d.". e section. display "Running section e.". f section. *> COBCH1664E perform range: f thru f display "Running section f.".