Address of parameter list generated by the CAMLST macro
Return code:
0=Successful
Any other value indicates an error. For further details see the IBM manual DFSMS DFP Advanced Services SC26-4921.
Parameter list, 20 bytes in length.
| Bytes | Description | 
|---|---|
| 0 | Bits Meaning 0=1 CVOL specified 1=1 CAMLST macro generated 2=1 CATALOG or CATBX specified 3=1 RECAT specified 4=1 UNCAT or UCATDX specified 5=1 Reserved 6=1 LOCATE by TTR specified 7=1 Reserved | 
| 1 | Bits Meaning 0=1 Do not allocate CVOL 1=1 BLDX or CATBX specified 2=1 BLDG specified 3=1 BLDA specified 4=1 LNKX specified 5=1 DLTX or UCATDX specified 6=1 DSCB TTR specified 7=1 RLTA specified | 
| 2 | Bits Meaning 0=1 DRPX specified 1=1 DELETE specified 2=1 RENAME specified 3=1 SYSZTIOT is enqueued exclusively 4=1 EMPTY specified 5=1 Reserved 6=1 Reserved 7=0 Caller supplied a CAMLST 7=1 Caller supplied a CTGPL | 
| 3 | Maximum generation count for a generation data group or zeros. | 
| 4-7 | Address of the data set name or TTR if byte 0, bit 6 is on. | 
| 8-11 | Address of the volume serial number of the CVOL catalog, or zeros if byte 0, bit 0 is zero. | 
| 12-15 | If CATALOG was specified, the address of the volume list. The address of an 8-byte area that contains an alias for a high-level index If LNKX was specified, the address of a 10-byte area that contains a 4-byte device code followed by the 6-byte volume serial number of the CVOL to be connected If the LOCATE macro was coded, the address of a 265-byte work area that must start on a doubleword boundary. if the issuer of LOCATE has a non-zero protect key, then the work area must have a matching storage protect key. | 
| 16-19 | Address of the DSCB TTR if CATALOG was specified and byte 1 bit 6 is set to 1. |