Trigger monitor listeners are automatically terminated when the enterprise server instance is stopped. However, you can also
               force termination of a trigger monitor listener using any of these methods: 
               	 
            
 
            	 
             
               		
               - Use the 
                  		  casout /o command. 
                  		
               
- Use a program to place the CSQ4TRMN:STOP message on the 
                  		  WebSphere MQ initiation queue that the trigger monitor monitors. 
                  		
               
- Submit 
                  		  CSQ4STOP.JCL using the 
                  		   JCL Control Page in ESMAC. 
                  		  CSQ4STOP.JCL is located by detault in 
                  		   
                  				 
                  				 
                  				  $COBDIR/src/enterpriseserver/ims/mq 
                  				   
                  			 . 
                  		
               
- Use an IBM-supplied utility such as 
                  		  amqsput or 