The format of the statements, positional operands and keywords are the
               		same as defined by your IBM mainframe IMS manuals. This
               		includes continuation rules, comments and labels except as noted here. 
            
             
               		
               - Up to 39 continuation lines are supported. More than 40 lines for one
                  		  statement generates a warning message and statement truncation. 
               
  
               		
               - Literal values cannot span more than two lines 
  
               		
               - All statements and keywords are assumed to be in upper case. Only
                  		  literal values are processed correctly if lower case. 
               
  
               		
               - In general, keywords or positional operands whose values must be
                  		  numeric are edited to ensure the value is numeric. If not numeric, you see a
                  		  warning message and the value is assumed to be zero. This can result in a
                  		  subsequent warning or severe error message depending on the keyword or
                  		  positional operand. All numeric values are limited to a maximum of eight
                  		  digits. 
               
  
               		
               - When the notes state the keyword and/or operand is edited, this
                  		  indicates that at least some editing of the keyword, operand and/or value is
                  		  performed. There is a complete list of the DBD, MFS and PSB warning and error
                  		  messages in the section Error Messages in the online Reference
                  		  help. 
               
  
               		
               - All keyword operands which specify the string "*NAME" are
                  		  eight character names which follow the convention for valid IBM mainframe
                  		  member names. These names are always assumed to be valid. 
               
  
               		
               - Except as noted, unrecognized keywords and/or values are ignored
                  		  
               
  
               		
               - Except as noted, language and macro control statements are ignored.
                  		  For example, PRINT, TITLE, EJECT, .AIF, .AGO. 
               
  
               		
               - There is no edit recovery or MFS syntax error recovery. MFSGEN
                  		  terminates when a severe error is encountered. MFSGEN does not try to recover
                  		  from severe syntax errors.