The <opt> option is required in OSVS COBOL programs to provide a length specification.
               	
            
            	
            	
            Note that it is optional in VS COBOL II programs since it can be defaulted to the LENGTH OF construct.
            	
            
               		
               			
               - System Action:
 
               			
               - An Unsupported Function abend is generated for the EXEC CICS statement and an ERROR is raised.
 
               		
               		
               			
               - Resolution:
 
               			
               - Correct the EXEC CICS statement by adding the required option and specifying an appropriate argument for the length.
 
               		
               		
               			
               - Module:
 
               			
               - cicsprep (dfhxc2pc)
 
               		
               		
               			
               - Destination:
 
               			
               - Source Listing, .TRL file, STDOUT