Restriction:  This topic applies only when the AppMaster Builder AddPack has been installed, and applies only to Windows platforms. 
               	 
            
            	 
            
               		
               		  
               - Generate Control Point Comments
                  		  
               
-  Check this to generate comments in programs identifying control events.
                  		  
               
- Generate Database calls
                  		  
               
-  Check this to generate your database access specifications into database calls. When testing the program teleprocessing functions
                  without accessing a database, uncheck this option to suppress the generation of database calls.
                  		  
               
- Error-Send-and-Quit Para defined by user
                  		  
               
-  Check this to prevent Online Express from generating the Error-Send-and-Quit paragraph in a stub, copybook, or in miscellaneous
                  code. When checked, you must code this paragraph yourself. The default is unchecked.
                  		  
               
- Generate InterScreen Moves
                  		  
               
-  Check this to move all fields on the primary screen to like-named fields on the screen specified by a user-coded SEND macro.
                  The default is unchecked.
                  		  
               
- Redisplay Record
                  		  
               
-  Check this to display the last record of a repeated record block when scrolling.
                  		  
               
- Improve Sql Looping
                  		  
               
-  Click this to generate two DB-PROCESS calls instead of one to improve runtime performance. Otherwise, only one DB-PROCESS
                  executes both the initial retrieval and the paging forward function.
                  		  
               
- Clear Screen with Spaces
                  		  
               
-  Click this to clear all I/O screen fields with spaces. This is the default for non-CICS applications.
                  		  
               
- Clear Screen with LowValues
                  		  
               
-  Click this to clear all I/O screen fields with low values. This is the default for CICS applications.
                  		  
               
- System Message Field
                  		  
               
-  Select a message field name.
                  		  
               
- Cursor on Field
                  		  
               
-  Select the screen field on which you want the cursor to initially appear.
                  		  
               
- Extra Commarea Bytes
                  		  
               
-  Type the size of the largest record that the program can send or receive.