Provides instructions for generating both console and Windows Forms client applications that can be used to access the deployed
                  Web service. 
                  	  
               
            
 
            	 
            Restriction: For service interfaces, the Microsoft Visual Studio Shell supports the generation of console clients only. To generate any
                  other type of client, you must install a full version of Visual Studio. 
               	 
            
 
            	 
            
               Generate the clients
 
               		 
               		
               The client generation process automatically produces a console client without further configuration; however, to simultaneously
                  generate a Windows Forms client, you must set a generation option. 
                  		
               
 
               		
                
                  		  
                  - From Visual Studio main menu, click 
                     			 Tools > Options. 
                     		  
                  
- Expand 
                     			 Micro Focus Tools, and then click 
                     			 Service Interfaces. 
                     		  
                  
- Check 
                     			 Windows Forms Application, and then click 
                     			 OK. 
                     		  
                  
- On the 
                     			 Solution Explorer, right-click the 
                     			 COMMWS service interface, and select 
                     			 Generate Clients from the context menu. 
                     		  
                  
You can watch the generation process in the 
                  		  
Output window. When it is complete, you should see the message 
                  		  
Generation succeeded. In the Solution Explorer, two new projects have been added to the solution: 
                  		
                  
 
                     		  
                     - COMMWSClientApp - the console client 
                        		  
                     
- COMMWSWinApp - the Windows Forms client 
                        		  
                     
Each new project contains the necessary client files to successfully access the COMMWS service now running on the CICSCA 
                  		  enterprise server region. 
                  		
               
 
               	 
              
            	 
            
               Register the proxy library
 
               		 
               		
               If you are running Visual Studio on Windows 7 or earlier, you might be required to register the Proxy Library after generating
                  a Windows Forms client for the first time. If your generation output contains the following message, follow the steps outlined
                  below: 
                  		
               
 
               		
                
                  		  Register proxy library COMMWSProxyWrapper.dll in "c:\tutorials\IMTK\CICSCommareaWS\COMMWSWinApp\Bin\Release". 
                  		
               
 
               		
                
                  		  
                  - Start an 
                     			 Enterprise Developer command prompt as an administrator. If you need instructions, see 
                     			 To start an Enterprise Developer command prompt as an administrator. 
                     		  
                  
- Change to the directory specified in the client generation output message. 
                     		  
                  
- Enter 
                     			 regsvr32 COMMWSProxyWrapper.dll. 
                     		  
                  
- Click 