| A 
                                    						  
                                  |  
                                 						  
                                 Specifies whether to allow ActiveX controls in your COBOL application to use classes and methods in the OLE class library;
                                    set -A to allow. 
                                    						  
                                  |  
                                 						
                              
 
                              						
                               
                                 						  
                                 | F 
                                    						  
                                  |  
                                 						  
                                 Specifies whether or not to fold method names invoked by the program being compiled to lower case. Use -F if your program
                                    calls Java methods, since Java method names are case-sensitive. See your 
                                    							 Java and COBOL book for information on using Java and COBOL together. 
                                    						  
                                  |  
                                 						
                              
 
                              						
                               
                                 						  
                                 | G 
                                    						  
                                  |  
                                 						  
                                 Specifies whether to make class data global for instances. The use of this option is not recommended. It is provided for compatibility
                                    with earlier releases. 
                                    						  
                                  |  
                                 						
                              
 
                              						
                               
                                 						  
                                 | L 
                                    						  
                                  |  
                                 						  
                                  Specifies whether to include directory location comments in 
                                    							 .cls and 
                                    							 .ins inheritance files. 
                                    						  
                                  |  
                                 						
                              
 
                              						
                               
                                 						  
                                 | P 
                                    						  
                                  |  
                                 						  
                                 Specifies whether to make parameter type information available to the run-time system. This is needed for messages sent to
                                    COM. The number of parameters in any method called or declared is limited to 31, plus an optional return value. 
                                    						  
                                  |  
                                 						
                              
 
                              						
                               
                                 						  
                                 | Q 
                                    						  
                                  |  
                                 						  
                                 Specifies whether to disable the use of: 
                                    							 
                                     
                                       								
                                       - IN and OF any place that could possibly follow a data name in the verb-signature of a method interface definition. 
                                          								
                                       
  
                                       								
                                       - Any verb in the verb-signature of a method interface definition. 
                                          								
                                       
  
                                       							 
                                      
                                    						  
                                  |  
                                 						
                              
 
                              						
                               
                                 						  
                                 | W 
                                    						  
                                  |  
                                 						  
                                 Specifies whether working storage means object storage in instances and factory (class) objects. 
                                    						  
                                  |  
                                 						
                              
 
                              					 
                            
                           				  
                         
Comments:
When working storage is used to mean object storage, an Object-Storage Section must not be specified.
The +W setting provides compatibility with the ISO 2002 COBOL standard.