-  
                  		  Log on to MFA Compare and Synchronization Monitor: 
                     		   
                  		    
                  			 
                   
                     		  
                     - From Eclipse, on the 
                        			 Run menu, select 
                        			 . 
                        		  
                     
- From an 
                        			 Enterprise Developer command prompt, enter 
                        			 mfmonmx2. 
                        		  
                     
 
-  
                  		  On the main toolbar, click 
                     			  (Add new rule). (Add new rule).The 
                     				Check Data Set Type dialog box appears. 
                     			 
                   
-  
                  		  Type the name of the data set to synchronize, set the organization type (if required), then click 
                     			 OK. 
                     		   
                  		    
                  			 
                  If the data set is valid, the 
                     				Add Rule dialog screen appears. 
                     			 
                   
-  
                  		  Click the box below 
                     			 Sync Mode and select one of the following: 
                     		   
                  		    
                  			 
                   
                     				
                     - BOTH - changes on either the mainframe or the workstation are synchronized 
                        				
                     
- UPLOAD - only changes on the workstation are synchronized to the mainframe 
                        				
                     
- DOWNLOAD - only changes on the mainframe are synchronized to the workstation 
                        				
                     
- MONITOR - mimics the BOTH setting without changes being made 
                        				
                     
 
-  
                  		  Click 
                     			 Binary Data Transfer to transfer PDS data sets in binary format. 
                     		   
                  		
               
-  
                  		  In the 
                     			 Member Type field, specify the type of member contained in an Endevor, Panvalet or Librarian container, if appropriate. 
                     		   
                  		
               
-  
                  		  If required, click 
                     			 Advanced and select one or more of the following options: 
                     		   
                  		    
                  			 
                  Note: These options apply to all active rules. 
                     			 
                    
                     				
                     - Delete workstation file if mainframe member is deleted - during synchronization, if a member has been deleted on the mainframe, it will also be deleted on the workstation. 
                        				
                     
- Delete workstation folder if library is deleted - during synchronization, if a library has been deleted on the mainframe, the workstation folder is also deleted if it contains
                        no other synchronized members. 
                        				
                     
- Handle embedded hex in MF MDECONV format - uses the MDECONV technique to deal with embedded hex values, that is, all translated hex values less than 
                        				  x'1f' have a null character inserted before the hex value, and the COBOL run-time system handles these embedded hex values. 
                        				
                     
- Suppress embedded hex warning messages - pop-up messages when a non-printing character is received from the mainframe are not displayed; an entry is recorded in
                        the log file instead. 
                        				
                     
 
-  
                  		  If required, click 
                     			 Filters, then add a simple or advanced filter: 
                     		   
                  		    
                  			 
                   
                     				
                     - To add a simple filter, in the 
                        				  Simple Filter field, enter a filter (for example AA* filters only on data sets that start AA), then click 
                        				  OK. 
                        				
                     
- To add an advanced filter, click 
                        				  Use Advanced Filters, 
                        				  Add Filters, click the required filter and select how the filter should work (Include or 
                        				  Exclude), then click 
                        				  OK. 
                        				
                     
 
-  
                  		  In the 
                     			 Directory field, enter the path of a workstation directiory to use for synchronization. 
                     		   
                  		
               
-  
                  		  In the 
                     			 File Extension field, enter the extension that will be applied to each member synchronized to the workstation. 
                     		   
                  		
               
-  
                  		  Click 
                     			 OK. 
                     		   
                  		    
                  			 
                  The rule appears on the main screen.