The 
                  		LOCKTYPE option specifies the type of record locking in use. 
                  	 
 
            	 
            
               Syntax:
 
               		 
               		
                
                  		    
                  			 LOCKTYPE 
                  			 = 
                  			 integer 
                  		    
                  		
               
 
               	 
              
            	 
            
               Parameters:
 
               		 
               		
                
                  		   
                  			 
                  - 0 
                     			 
                  
- Programs can read locked records, but cannot access them in other ways. This is the standard method with this COBOL system.
                     
                     			 
                  
- 1 
                     			 
                  
- Programs cannot access locked records at all. This is as in languages other than COBOL. 
                     			 
                  
- 2 
                     			 
                  
- Creates a new file with the same base name as the file being opened but with a 
                     				.lck extension. Any record locks are recorded in this file.